Contact Sitemap Project-File Home  
 
 
Home > Installation > Installation Recommendations > Special Installation and Accessories
Stair nosings, stair angles

nora® profiles are made of rubber.

Contact or dispersion adhesive may be used for fixing the nora® profiles (after prior consultation with the adhesive manufacturers concerned).

The subfloor

The subfloor must be dry. Porous, sanding or dusty subfloors are treated with commercially available primer. Uneven or excessively rough subfloors either at the wall or the floor are levelled and smoothed with commercially available levelling or smoothing compound.

Please follow the recommendations of the manufacturers of primers, levelling compounds and adhesives.

At the time of installation and of adhesive bonding, the subfloor temperature must be not less than 15 °C.

Important: The vertical nosing section is not fixed.
Exception: stair nosings with riser section.

General remarks

As a string casing for right-angled steps, step angles for wall and banister sides are offered.

Stair angles

For the wall
side

TW 7006 U
Outer angle

 
 
 
 
 TW 7005 U
Inner angle

Stair angles

For the banister
side

TG 7004 U
Outer angle

 
 
 
 
 TG 7003 U
Inner angle

Same cross-section as
skirting S 1008 U
Same cross-section as
stringer A 5013 U

First the stair angles are cut to size using the profile cutter.
To do this, they are placed on top of each other and fitted to the step, and then cut all together.

After that, they can be glued together indissolubly with fast-setting adhesive.

The rod profiles, all of which have the same cross-section, form the continuation at the open landing edge.

After that, cut the stair nosing to size, and fix it.

Then fit the step covering in place, and fix it.

All profiles are fixed with contact adhesive.

The stair nosing T 5044 with a "slide-in lip", i.e. a lip covering the separating line between the flooring and the stair nosing. The visible length of the tread section is 7.4 cm. (T 5019 A = 5 cm) This length is required to have this stair nosing glued with SIGA Stepform and/or nora Stepfix (see special installation recommendation).

At the time of installation, nora® profiles must have the same temperature as the subfloor. In winter, therefore, nora® profiles have to be stored for some days at installation temperature.

Installation and fixing

Contact adhesive
The adhesive is applied abundantly with a brush to the subfloor and to the back of the profile. (It is not necessary to sand the back of the profile.)

Airing time will depend on the temperature and humidity and can be checked by means of the touch test. The adhesive must still be sticky without being tacky.

The adhesive film will dry faster on rubber profiles than on PVC profiles.

Immediately after being positioned, the profile is carefully pressed down, and perhaps hammered into place (mallet).

 

 

   
 
Top of the Page   Put this Page in your Project-File   Print this Page   Send this Page via eMail  

 

Copyright © nora systems GmbH 2007 - Imprint - Disclaimer