Home > Installation > Installation Recommendations > Special Installation and Accessories
Skirting formation with noraplan® |

-
As per VOB DIN 18 365, the surface must be level, permanently dry, dust-free, tension and compression-proof. Apply suitable dispersion primer to dusty surfaces. The surfaces
may not have structure heights above 0.6 mm, if
necessary, level out.
-
Mark a line with a ruler of 10 cm width along the wall on a surface which has been prepared properly and professionally.
-
Position noraplan® and cut the seams.
-
Apply adhesive exactly up to the marking and install the covering after airing. Cut off the floorcovering with the steel ruler of 10 cm width flush along the wall (figures 1/2).
 figure 1
 figure 2
-
Cut cushioned-edge profile to size. Cut to mitre outer and inner edges with profile strip shears.
-
Cut to size (19 cm) the floorcovering strips required for skirting formation and cut the inner and outer edges with the nora® template.
-
Install nora® Profix at the wall using the supplied roll-off disc and rub thoroughly into place. Cut off approx. 2 cm of pro-tective paper and install the cushion-edge profile (figures 3/4).
 figure 3  figure 4
-
Install nora® Profix installation band approx. 2 mm from the
floorcovering edge and rub thoroughly into place (figure 5).
 figure 5
-
Remove protective paper from the floor, place covering strip flush to the previously installed coverings. Then, remove the protective paper at the wall and complete instal-lation
of the covering (figure 6).
 figure 6
-
The seams to the floorcovering are joint-sealed with the hand-operated hot-welding gun or welding machine. The inner and outer corners as well as butt joints must be joint-sealed using the nora® joint sealing compound.
|